Technical Data


CyberRow Technical Data

Total cooling capacity (kW) 22.5–58.2
Volumetric airflow (m³/h) 4,600–11,200
Size 1–6

 

CyberRow Technical Data in detail

CyberRowDXGECW
Model CRS/CRL 211 ASCRS/CRL 251 AS/GSCRS/CRL 361 AS/GSCRS/CRL 251 GESCRS/CRL 361 GESCRS/CRL 210 CWCRS/CRL 320 CWCRS/CRL 560 CW
Heightmm1.9501.9501.9501.9501.9501.9501.9501.950
Depthmm1.200/1.3751.175/1.3751.175/1.3751.175/1.3751.175/1.3751.175/1.3751.175/1.3751.175/1.375
Widthmm300400600400600300400600
Cooling capacity (1) kW22,225,337,525,337,522,733,358,2
Cooling capacity Indirect Free Cooling(2) kW---23,734,6---
Airflowm3/h4.6005.4008.0005.4008.0005.0006.40011.200

1) Return air conditions: 35°C, 25% R.H.; DX-units: Condensation temperature 45°C; CW-units: Water inlet temperature 10°C / Water outlet temperature 15°C, Glycol percentage 0%

2) Return air conditions: 35°C, 25% t.H.; Water temperature 10°C/15°C,0% Glycol percentage

Login on E-Stulz

for detailed technical specs

To top