General Info

Test Center


High Performance Engineering

STULZ has its own professional Test Bench in Toledo (Spain) to simulate all the requirements and special conditions of its units.

Test Center
Test Center
The highest capacity Test Center in Europe
Software
Software
Live broadcasting of the FAT (Factory Acceptance Test)
High Performance
High Performance
Air flows up to 240.000 m3/h and a 800kW IT load
Self Development
Self Development
Self depeloved Test Center in Spain´s production plant
Stringent tests of capabilities, systems and components performance

Stringent tests of capabilities, systems and components performance

Great capacity Test Center, the highest capacity and accurate in Europe allows to test the most demanding technical specifications, with the possibility to test air flows up to 240.000 m3/h and a 800 kW IT load, assisted by sophisticated software of parameterization and monitoring.

Units can be tested and optimized, even during the design and development phase, taking into account different temperature conditions, possible security failures, and parameters to proof current and real performance capabilities, energy and water consumption.

 

 

 

Technical Characteristics

  • Area 1.100 m²

  • 2 parallel units test capability

  • Sophisticated parameterization and monitoring software

  • Design airflow 140.000 m³/h

  • Maximum airflow 240.000 m³/h

  • Data Room Loading - 800 kW

  • Functional test simulating security failures

  • Temp. environmental simulation: + 10º to + 50º DB, design flow

 

 

Self-developed Test Center

Discover the wide range that STULZ Tecnivel adapts to your projects, providing the added value of experience and quality, as well as the high technology inherent in all its equipment.

Our main objective is the development of innovative and specialised solutions according to the needs of our customers and market trends, for this we have an R&D engineering department supported by a team of professionals from different areas who know the specific needs of the HVAC market.

Ensuring proven quality and compliance of your purchased unit 


STULZ has developed the live broadcasting of the FAT (Factory Acceptance Test) so that customers can witness the testing of their equipment, without the need to travel to our production plant.

They can monitoring their project and review compliance with the project’s contractual obligations by watching the FAT from anywhere in the world. This efficient and secure tool has provided a solution to the current difficulties of security and travel, bringing significant cost and delivery time savings and offering complete flexibility to our customers.

 

Details

Air Distribution

High versatility to test different unit configurations

Adapting duct´s layout to each project, diverse and multiple air distribution can be achieved according to the different customer´s installation needs.

Diverse test options are technically possible, taking into account different air flow directions and especifications of the unit.

 

HH Air distribution

Horizontal – Horizontal

VV Air distribution

Vertical – Vertical

VH Air distribution

Vertical – Horizontal

Some Figures

Measurement cutting-edge technology

The individual test instruments are connected to the test center control system, which transfers the measured values to the master computer where the current values are displayed and recorded. Based on these recorded measured values, the reference data are calculated.

 

 

  • 80 EC Fans
  • 100 G4+F7 Filters
  • 6 Load Banks
  • 172 Damper Actuators
  • 106 T/H Sensors
  • 72 Diff. Press. sensors
  • 4 Heat Exchangers
  • 4 Hot Water Coils
  • 4 Chilled Water Coils
Simulation

Environmental and climatic simulation

STULZ´s Test Center is able to simulate a wide variety of environmental testing and climatic test conditions to recreate those encountered by units, parts or test components in field use.

This external air climatic simulation is recreated in a building with state of the art components and instruments to reach accuracy and precision.

A – Dampers, Outdoor Air Filters and Water Coils.
B – Heat Exchangers, Fan-wall for exhaust air and dampers.
C – Hot Water Coils in 4 CyberAir units.
D – Fan-wall for external air simulation supply.
E External Air Simulation to Air Handler Units.
F – Exhaust Air from Air Handler Units and mix dampers.

Benefits

Benefits

  • The certainty that you are choosing the right air conditioning system.
  • Test center certified and calibrated
  • Certainty in the calculation of operating costs.
  • Specific test for each country.
  • Infinite adjustment of  voltages and frequencies
  • Documentation of calibration certificates and test results. Simulation of different operating states
  • Use of ultra-modern and adjustable equipment according to different equipment sizes

 

 

 

 